APP paras of Edgebus ​

This document provides a detailed guide for R&D and technical support personnel on configuring EdgeBus functions using App parameters. The EdgeBus parameter architecture is clearly structured into three main categories: Version Information, Running Parameters, and System Information, facilitating user understanding and operation.

Target Reader ​

This document is primarily intended for R&D Engineers and Technical Support Engineers who need to perform in-depth integration and debugging with EdgeBus devices.

Getting Started with Configuration ​

Please refer to the document of RPC

Version Information ​

Version Information parameters provide the firmware and hardware identifiers for the EdgeBus device. This section occupies 8 bytes in total, and all data is read-only.

AddressLengthPermissionFieldDescription
01BRead-onlyfuotaversion hwtypebit0-bit3: FUOTA version number. During a FUOTA upgrade, the version number in the data packet must match this value.
bit4-bit7: Lower 4 bits of hardware model (12 bits total).
11BRead-onlyhwtypeUpper 8 bits of hardware model (12 bits total).
21BRead-onlylen
hwversion
bit0-bit3: Number of bytes to copy during a FUOTA upgrade, as 4 * (len + 1).
bit4-bit7: Hardware version , range 1-15.
31BRead-onlyswversionSoftware version number, range 1-255.
4-52BRead-onlybztypeModel of the connected service device.
61BRead-onlybzversionService parameter version number.
71BRead-onlyfiltermask
otamask
checkOk
bit0-bit2: filtermask.
bit3: Reserved.
bit4-bit6: otamask.
bit7: checkOk flag.

Running Parameters ​

Running Parameters define the working mode and core functions of the EdgeBus during operation. This section occupies 16 bytes in total.

AddressLengthPermissionFieldDescription
81BR/WfieldMode
RelayEnable
bit0: fieldMode.
bit1: RelayEnable, set to 1 to enable the relay function.
bit2-bit7: Reserved.
91BWriteFunction TriggerUsed to trigger specific EdgeBus actions:
- Write 1: Reset the device.
- Write 2: Execute all query and upload tasks.
- Write 4: Rejoin the network.
101BR/WResvReserved.
111BR/WWake-up & Channel Configbit0: Set to 1 to allow waking up EdgeBus via a low-level input on the PC6 pin.
bit1: Set to 1 to output a low level on PC2 to wake up the client MCU before sending data via UART.
bit2-bit3: Reserved.
bit4-bit6: Uplink channel selection (0: LoRaWAN, 1: 4G).
bit7: Reserved.
121BR/WSerial Baud RateValue is Serial Baud Rate / 12. For example, for a 9600 baud rate, this value should be 800.
131BR/WSerial Comm. Paramsbit0-bit3: Data bits.
bit4-bit5: Stop bits.
bit6-bit7: Parity bit (0: None, 1: Odd, 2: Even).
Note: Data bit settings for even parity differ across hardware platforms:
- OMx11: For 8 data bits with even parity, set data bits (bit0-bit3) to 9 and parity (bit6-bit7) to 2.
- OMx22: For 8 data bits with even parity, set data bits (bit0-bit3) to 8 and parity (bit6-bit7) to 2.
141BR/WWorking Modebit0: Set to 1 to keep EdgeBus in a constant receiving state, suitable for applications where connected devices actively upload data.
bit1: Set to 1 to enable low-power mode.
bit2: Set to 1 to exchange data with the connected device via UART1.
bit3: Set to 1 to enable transparent (passthrough) mode.
bit4: Channel selection (0: LoRaWAN, 1: Lora).
bit5: Set to 1 to enable automatic network rejoin on power-up.
bit6: Set to 1 to have EdgeBus send its own information via the Lora channel after power-up.
bit7: Set to 1 to have EdgeBus complete time synchronization, mode switching, etc., within 60 seconds of power-up.
151BR/Wconfirm Duty CycleWhen the uplink packet sequence number is an integer multiple of this value, a confirm packet is sent; otherwise, an unconfirm packet is sent.
161BR/WParam. R/W PortPort number for reading or setting EdgeBus parameters.
171BR/WTransparent Channel PortCommunication port number for transparent mode.
18-192BR/WScheduled Reset PeriodEdgeBus will reset periodically according to the hours set here.
20-234BR/WUplink Time OffsetUnit is milliseconds (ms). This offset is added when EdgeBus uploads data. Usually set to 0.

System Information ​

System Information parameters provide real-time data about the EdgeBus hardware status and environment.

AddressLengthPermissionFieldDescription
241BR/WbatterybaseBattery level base value.
25-284BR/WUTC TimeSeconds since January 1, 1970.
29-302BRead-onlyChip TemperatureActual Temperature (°C) = (Read Value - 1000) / 10.
311BRead-onlyChip Supply VoltageSupply Voltage (V) = (Read Value / 254 * 1.6) + 2.
32-332BR/WQuery Timeoutbit0-bit13: Timeout value.
bit14-bit15: Timeout unit (0: seconds, 1: minutes, 2: hours, 3: days).
341BR/WTimeout Retry CountNumber of retry attempts after a query times out.
351BR/WSerial Data Calibrationbit0: Set to 1 to enable serial data calibration.
bit1-bit2: Calibration method (0: OR, 1: AND, 2: Direct Replace).
bit3-bit7: Reserved.
361BR/WSerial Calibration GroupsDefines the number of calibration rules. Rules start at address 170, with each 3-byte group defining the start index, length, and calibration value.
371BR/WPeriodic Rejoin PeriodThe interval at which the device performs a periodic network rejoin.
38-392BR/WPeripheral Power-on DelayUnit is milliseconds (ms). For low-power products, this ensures the peripheral's power supply (e.g., for RS485) is stable before it performs an operation.
40-434BR/WHeartbeat IntervalHeartbeat Interval Unit in seconds.
44-5916BRead-onlySystem ReservedSystem reserved.
601BR/Wsub_device_countsNumber of connected devices in multi-device mode.
61-644BRead-onlySystem ReservedSystem reserved.
651BR/Wquery_indexStarting index of device address in query command.
661BR/Wsub_addr_sizeLength of sub-device address in multi-device mode.
67-nBR/Wsub_addrSub-device addresses in multi-device mode, based on sub_addr_size:
- Device 1: 67 ~ 67 + sub_addr_size - 1
- Device 2: 67 + sub_addr_size ~ 67 + 2×sub_addr_size - 1
- Device N: 67 + (N-1)×sub_addr_size ~ 67 + N×sub_addr_size - 1

Other Parameters ​

User-Open Address Space ​

● Address Range: 70 - 200

Description: This address space is reserved for user's free use and can be utilized to store custom data.

70–110: Store intervals (e.g., polling or upload intervals) in units of 4 bytes representing seconds.

110–150: Storage area for COV (Change of Value) thresholds.

150–200: Storage area for sub-device addresses or other user-defined data.

DTU Configuration Best Practices ​

Heartbeat and Power-On Delay ​

⚠️ Important: A factory-default EB-DTU has no EB application pre-loaded. Its heartbeat interval defaults to 3600 s (1 hour) and must be configured via a parameter SET RPC or a device configuration template before any production use.

Recommended values (effective from integration revision A17):

ParameterAddressRecommended ValueReason
Heartbeat interval (period_heart)40–4386400 s (24 h)Reduces radio transmissions and extends battery life. Replaces the earlier 8 h / 28800 s recommendation.
Peripheral power-on delay (pwron_delay)38–39≥ 100 msUltrasonic transducers and RS-485 sensors need stabilisation time after power-on. A delay shorter than 100 ms causes intermittent UART/RS-485 query timeouts (uplink status byte 0x02). Exact value depends on the sensor's power-on specification.

Synchronised SET RPC: whenever you send a SET RPC to configure the collection or upload interval, also set pwron_delay and period_heart in the same call. Configuring the interval alone without aligning heartbeat and power-on delay leads to hard-to-reproduce timing issues in the field.

Default delivery path for pwron_delay:

  • getOtaConfig does not support setting the firmware default for pwron_delay.
  • Use a device configuration template (shared_attrs.pwron_delay.dftValue) combined with a SET RPC to push the value on first connection.

This guidance applies from integration revision A17 onwards. Devices already deployed with earlier settings do not require retroactive reconfiguration.