EdgeBus hardware family

Run EdgeBus on hardware built for the field

From the compact DC-powered KC25 beside industrial equipment to battery-powered IP65 collectors, choose an EdgeBus host by interface, power and installation environment.

Available now
3 devices
Product roadmap
1 device
KC25 KC25 black aluminium LoRaWAN RS-485 collector with antenna connector and four status LEDs
RS-485
KC21 KC21 white IP65 LoRaWAN RS-485 collector with antenna
RS-485 · controlled 15V output
KC22 KC22 white IP65 LoRaWAN M-Bus collector with antenna
M-Bus
EDGE RUNTIMEKC × EdgeBus
Available now

Three hardware forms, one continuously updateable runtime

KC25 is the flagship EdgeBus collector, with KC21 and KC22 covering low-power RS-485 and M-Bus sites. All three share edge collection, processing, COV and remote-update capabilities.

CURRENT / 01 KC25 black aluminium LoRaWAN RS-485 collector with antenna connector and four status LEDs Flagship
KC25

Compact DIN-rail RS-485 collector

The compact aluminium flagship for industrial RS-485 collection, bringing configurable protocol parsing, COV and remote business-program updates closer to the equipment.

INTERFACE
RS-485
POWER
External DC 5–24V power
LORAWAN
Class C
PROTECTION
IP53
MOUNTING
DIN rail
FIELD FIT
  • Industrial equipment
  • Control cabinets
  • Metering and monitoring
EDGEBUS
  • EdgeBus VM
  • COV and alarms
  • FUOTA
CURRENT / 02 KC21 white IP65 LoRaWAN RS-485 collector with antenna Available now
KC21

IP65 RS-485 collector

For low-power or unpowered sites. It can supply 15V to an external sensor during collection and reuse installed RS-485 devices.

INTERFACE
RS-485 · controlled 15V output
POWER
Battery or DC power
LORAWAN
Class A on battery · Class C on external power
PROTECTION
IP65
MOUNTING
Wall mount
FIELD FIT
  • Water-quality sensors
  • Utility corridors and pits
  • Installed sensor retrofit
EDGEBUS
  • EdgeBus VM
  • COV reporting
  • FUOTA
CURRENT / 03 KC22 white IP65 LoRaWAN M-Bus collector with antenna Available now
KC22

IP65 M-Bus collector

A low-power LoRaWAN collection path for M-Bus water and heat meters, designed for metering clusters and sites without mains power.

INTERFACE
M-Bus
POWER
Battery or external DC 5–24V power
LORAWAN
Class A on battery · Class C on external power
PROTECTION
IP65
MOUNTING
Wall mount
FIELD FIT
  • Water meters
  • Heat meters
  • M-Bus metering
EDGEBUS
  • EdgeBus VM
  • Data recombination
  • FUOTA
Selection matrix

Start with field conditions, then choose the hardware

The interface determines what connects; power and protection determine where it installs.

SpecificationKC25KC21KC22
Field interfaceRS-485RS-485 · 15V outputM-Bus
PowerDC 5–24VBattery or DCBattery or DC 5–24V
LoRaWAN ClassClass CClass A / Class CClass A / Class C
ProtectionIP53IP65IP65
InstallationDIN railWall mountWall mount
Typical siteIndustrial equipment and cabinetsLow-power RS-485 sensorsWater and heat meters

Detailed specifications are subject to the ordered model and latest technical manual.

One runtime

Different hardware, one EdgeBus data path

Collect, process and organize uplinks at the endpoint, turning a field bus into a remotely maintainable LoRaWAN data path.

  1. 01Protocol collectionRead RS-485 or M-Bus devices
  2. 02Business runtimeRun collection logic in EdgeBus VM
  3. 03AggregationMerge multiple reads into one payload
  4. 04COVSample frequently, report changes
  5. 05FUOTAUpdate business programs remotely
  6. 06LoRaWANLow-power wide-area uplink
Product roadmap

Expanding where EdgeBus can be installed

The next planned model extends EdgeBus into demanding solar-powered outdoor sites. It is not part of the currently supported list.

Planned

KC26

Solar outdoor EdgeBus endpoint

For outdoor sites without fixed power and with higher environmental protection requirements.

POWER
Solar powered
ENCLOSURE
Aluminium enclosure
POSITIONING
High-protection outdoor product
Focused on solar energy and outdoor protection; no specific IP rating or interface is claimed at this stage.

The EdgeBus device family will continue to grow. Final specifications and availability are subject to official product release.

Choose the EdgeBus host, then connect the field device